Podaci koje je potrebno zabilježiti u operaciji reverzne osmoze, ne propustite.

Dobrodošli da nas kontaktirate WhatsApp
Travnja 19 2023

Sažetak podataka koje je potrebno zabilježiti u operaciji reverzne osmoze, ne propustite.


A summary of the data that needs to be recorded in the reverse osmosis operation, don't miss it.

Zašto bilježiti početne radne podatke

During the operation, the operating conditions of the system, such as pressure, temperature, system recovery rate and feed water concentration, may change and cause changes in product water flow and quality. In order to effectively evaluate the performance of the system, it is necessary to compare products under the same conditions Water flow and quality data, because it is impossible to always obtain these data under the same conditions, it is necessary to "normalize" the RO performance data under the actual operating conditions according to constant operating conditions in order to evaluate the performance of the RO membrane. Standardization includes "normalization" of product water flow and "normalization" of salt breakthrough.

Ako su radni uvjeti sustava isti kao kad je prvi put pušten u rad, protok koji se sada teoretski može postići naziva se standardizirani protok.

Ako su uvjeti rada sustava isti kao kad je prvi put pušten u rad, stopa desalinizacije koja se sada teoretski može postići naziva se standardizirana stopa desalinizacije.

Iz gornje definicije možemo znati da su referentna točka za standardizaciju podaci o radu u vrijeme početnog rada (stabilan rad ili nakon 24 sata) ili standardni parametri proizvođača membranskog elementa reverzne osmoze. U ovom trenutku membrana reverzne osmoze u osnovi nije pogođena. Za svako onečišćenje u budućnosti potrebno je procijeniti postoji li onečišćenje u reverznoj osmozi i treba li ga očistiti, a potrebno ga je procijeniti na temelju podataka u trenutku početnog rada. Stoga su podaci u trenutku početnog rada posebno važni i moraju se zabilježiti.

Dnevna evidencija o radu trebala bi sadržavati ove sadržaje   

Zapis o pokretanju

Karakteristike učinkovitosti RO postrojenja moraju se dokumentirati od samog početka. Izvješće o pokretanju treba sadržavati potpuni opis postrojenja. Dijagrami toka, dijagrami postrojenja mogu se koristiti za predstavljanje predobrade, RO postrojenja i naknadne obrade, početne predobrade i zapisa o performansama RO.
All gauges and meters must be calibrated and documented in accordance with the manufacturer's recommendations.

Podaci o radu RO
Radni podaci mogu se objasniti. Za performanse RO sustava sve podatke treba prikupljati i bilježiti tijekom cijelog životnog vijeka RO. Ovi podaci, zajedno s redovitom analizom vode, pružaju informacije za procjenu performansi RO jedinice.
1. Protok (voda proizvoda i koncentrirani protok vode svakog dijela).
2. Tlak (sve razine opskrbe vodom, koncentrirana voda, voda proizvoda).
3. Temperatura (napojna voda).
4. pH vrijednost (napojna voda, voda proizvoda, koncentrirana voda).
5. Vodljivost/TDS (napojna voda, voda proizvoda, svaki dio napojne vode, koncentrirana voda proizvoda).
6. SDI (napojna voda, nakon filtracije od 5 mm, svaki dio napojne vode, koncentrirana voda).
7. LSI posljednje koncentrirane vode.
8. Radno vrijeme.
9. Povremeni događaji (SDI, poremećaji pH i tlaka, prekidi itd.).
10. The calibration of all instruments and meters must be carried out in accordance with the manufacturer's recommended method and cycle, but at least one calibration (correction) is required every three months.
11. Tlak protoka, temperatura, pH vrijednost, vodljivost, SDI (opskrba vodom), jednom u smjeni.
12. SDI svakog dijela napojne vode i koncentrirane vode jednom tjedno i analizirajte ostatke na membrani filtra.
13. TDS svakog dijela napojne vode, koncentrirane vode i vode proizvoda analizira se jednom mjesečno.
14. Preostali klor i vodljivost jednom dnevno.
15. Koncentrirana voda (drenaža) LSI jednom tjedno.
16. Zabilježite slučajne događaje kako se događaju.

Podaci o postupku doziranja
1. SDI jednom dnevno prije i nakon dodavanja kiseline.
Ulazni i izlazni tlak filtra od 2,5 mm jednom u smjeni.
3. Konzumacija kiseline jednom dnevno.
4. Konzumacija NaClO jednom dnevno.
5. Konzumacija NaHSO3 jednom dnevno.
6. The calibration of all instruments and gauges shall be in accordance with the manufacturer's recommendations and methods, but shall be calibrated at least once every three months.
Dnevnik održavanja
Evidencija o održavanju mora se voditi, ona može pružiti informacije o performansama permeatora i mehaničke opreme

Dodatne informacije, uključujući sljedeće:
1. Rutinsko održavanje.
2. Mehanički kvar/zamjena.
3. Zamjena reverzne osmoze/tlačne posude/membranskog elementa.
4. Čišćenje (sredstvo za čišćenje i uvjeti čišćenja).
5. Zamijenite filtarski element od 5 mm.
6. Kalibracija instrumenata i brojila.

Postavite svoja pitanja